Items |
BAY2180-15 Air Relief Valve for Trailer Female NPT 15 psi Price $105.83
|
BAY2180-18 Air Relief Valve for Trailer Female NPT 18 psi Price $105.83
|
BAY2182-15 Air Relief Valve High Capacity for Blower Male NPT 15 psi Price $111.14
|
BAY2182-18 Air Relief Valve High Capacity for Blower Male NPT 20 psi Price $111.14
|
BAY2180RK15 Rebuild Kit 2180 Relief Valve 15 psi Price $84.14
|
|||||
Description |
N/A
|
N/A
|
N/A
Dixon Bayco has redesigned the 2182 series of Bayco relief valves. The 2182 series of blower relief valves, (not to be confused with the A2182 series designed for trailer service) have a temperature compensated pressure relief setting. The 2182 valve will relieve at the ordered set pressure at a temperature of 204ºC / 400ºF. At room temperature (73ºF / 22ºC) the 2182 valve will relieve approximately 4 psi higher than the ordered set pressure. A new label shows the relief pressure at 73ºF / 22ºC (for testing purposes), plus the relief pressure at the blower operating temperature (204ºC / 400ºF). Depending on the blower type, amount of vibration and operating temperature a difference of observable set pressure may occur. Room temperature testing will show different results. Example: 2182M-18 is set for 18 psi pressure relief while at an operating temperature of 204ºC / 400ºF. This same valve will test at 22 psi while at room temperature and a stable work bench. Both set points are listed on the new label. For proper use and testing, please read the installation instructions included with the product (also available on our website). Blower Service 2182 Series The 2182 series of air relief valves are designed for use in elevated temperature applications associated with blower service.
|
N/A
Dixon Bayco has redesigned the 2182 series of Bayco relief valves. The 2182 series of blower relief valves, (not to be confused with the A2182 series designed for trailer service) have a temperature compensated pressure relief setting. The 2182 valve will relieve at the ordered set pressure at a temperature of 204ºC / 400ºF. At room temperature (73ºF / 22ºC) the 2182 valve will relieve approximately 4 psi higher than the ordered set pressure. A new label shows the relief pressure at 73ºF / 22ºC (for testing purposes), plus the relief pressure at the blower operating temperature (204ºC / 400ºF). Depending on the blower type, amount of vibration and operating temperature a difference of observable set pressure may occur. Room temperature testing will show different results. Example: 2182M-18 is set for 18 psi pressure relief while at an operating temperature of 204ºC / 400ºF. This same valve will test at 22 psi while at room temperature and a stable work bench. Both set points are listed on the new label. For proper use and testing, please read the installation instructions included with the product (also available on our website). Blower Service 2182 Series The 2182 series of air relief valves are designed for use in elevated temperature applications associated with blower service.
|
N/A 2180/15 Repair kit, 15 psi spring (+2/-0 PSI tolerance), Spring Seat, Diaphragm, Valve plate, Bolts, Lockwashers, Tamper Proof Seal and Valve label | |||||
Package Type | N/A Each | |||||||||
Units Per Package | N/A 1 | |||||||||
Size | N/A 2 " | |||||||||
Body Material | N/A Aluminum | N/A Aluminum | N/A Aluminum | N/A Aluminum | N/A | |||||
Seal Material | N/A Silicone Rubber | |||||||||
Manufacturer | N/A Dixon Bayco | |||||||||
Vendor Item # | N/A 2180/15 | N/A 2180/18 | N/A 2182/15 | N/A 2182/18 | N/A 2180RK15 | |||||
Weight | N/A 4.15 lb | N/A 4.15 lb | N/A 4.15 lb | N/A 4.15 lb | N/A 1 lb | |||||
Note | N/A | N/A | N/A At 73ºF / 22ºC the 2182 series valves will relieve at 4 psi higher than the ordered pressure setting. | N/A At 73ºF / 22ºC the 2182 series valves will relieve at 4 psi higher than the ordered pressure setting. | N/A | |||||
Qty Req'd for Discount | N/A 3 | N/A 3 | N/A 3 | N/A 3 | N/A | |||||
% Discount at Checkout | N/A 7 % | N/A 7 % | N/A 7 % | N/A 7 % | N/A | |||||
|