Catalog

We stock vents for Knapp manholes. Please contact our parts department for info.
Unit of Measure
Items
Betts PPV Vent

Dome Vent PPV PAF 406
Price $60.87

Betts PPV Vent

Dome Vent PPV PAF 406
Price $60.87

Betts PPV Vent

Dome Vent PPV PAF 306
Price $60.25

Dome Vent Inbreathing Only

Dome Vent Inbreathing Only
Price $57.21
Description N/A Black Rating Disc for 6496ALB DOT 406
  • Dual Purpose Vent
  • Roll Over Protection
  • Compact Design
  • Interior Mount
A normal vent designed for use on MC306 & DOT406 cargo tanks. Model 6496 has a pressure setting per 178.346-3(b)(2) of "not less than 1 PSIG" and a vacuum setting per 178.346-3(c)(2) "no more than 6 ounces" which allows for efficient recovery of vapors during closed system loading and offloading. Unique roll over protection retains product at any attitude of rollover. Vent is flow tested and marked.
N/A
  • Dual Purpose Vent
  • Roll Over Protection
  • Compact Design
  • Interior Mount
A normal vent designed for use on MC306 & DOT406 cargo tanks. Model 6496 has a pressure setting per 178.346-3(b)(2) of "not less than 1 PSIG" and a vacuum setting per 178.346-3(c)(2) "no more than 6 ounces" which allows for efficient recovery of vapors during closed system loading and offloading. Unique roll over protection retains product at any attitude of rollover. Vent is flow tested and marked.
N/A Alum Non-Painted for 6238ALB DOT 306
  • Dual Purpose Vent
  • Roll Over Protection
  • Compact Design
  • Interior Mount
A normal vent designed for use on MC306 & DOT406 cargo tanks. Model 6496 has a pressure setting per 178.346-3(b)(2) of ""not less than 1 PSIG"" and a vacuum setting per 178.346- 3(c)(2) ""no more than 6 ounces"" which allows for efficient recovery of vapors during closed system loading and offloading. Unique roll over protection retains product at any attitude of rollover. Vent is flow tested and marked.
N/A Designed to supplement the 6238AL vent to provide additional inbreathing capacity when required. This vent may be used singly or in multiples according to requirements.
Package Type N/A Each
Units Per Package N/A 1
Body Material N/A Aluminum
Seal Material N/A Buna N/A Polyethylene N/A Buna N/A Viton®
Manufacturer N/A Betts
Vendor Item # N/A 6496ALB N/A 6496ALPE N/A 6238ALB N/A 6234ALB
Weight N/A 1 lb N/A 1 lb N/A 1 lb N/A .25 lb
Warning N/A Use only Betts Industries, Inc replacement components. Use of substitute parts can impair the proper function of this product and void all warranties. N/A Use only Betts Industries, Inc replacement components. Use of substitute parts can impair the proper function of this product and void all warranties. N/A Use only Betts Industries, Inc replacement components. Use of substitute parts can impair the proper function of this product and void all warranties. N/A
Inspection & Maintenance N/A Per TTMA Technical Bulletin No. 92 "Inspect pressure relief valves and normal pressure/vacuum valves with sufficient frequency, but no less than once a month, to insure they are operational. Corroded parts must be replaced. Valves that are filled with residue must be cleaned. If venting devices are not operational, do not operate the cargo tank until the venting devices are repaired or replaced. Failure to follow this procedure can result in liquid or vapor leakage and tank damage."

To inspect vent, remove from tank and check for obstructions in the exit port and pressure inlets. Shake vent to ensure roll-over guide block (#5) slides freely up and down. The vacuum disc (#14) is spring-loaded and should open approximately 1/8" to expose vacuum seat when the hex nut (#16) is gripped with a pair of pliers and pulled directly down.

Dirt and residue can be cleaned from the vent by soaking in mild detergent, rinsing with clean water, and blowing out with compressed air.
N/A Per TTMA Technical Bulletin No. 92 "Inspect pressure relief valves and normal pressure/vacuum valves with sufficient frequency, but no less than once a month, to insure they are operational. Corroded parts must be replaced. Valves that are filled with residue must be cleaned. If venting devices are not operational, do not operate the cargo tank until the venting devices are repaired or replaced. Failure to follow this procedure can result in liquid or vapor leakage and tank damage."

To inspect vent, remove from tank and check for obstructions in the exit port and pressure inlets. Shake vent to ensure roll-over guide block (#5) slides freely up and down. The vacuum disc (#14) is spring-loaded and should open approximately 1/8" to expose vacuum seat when the hex nut (#16) is gripped with a pair of pliers and pulled directly down.

Dirt and residue can be cleaned from the vent by soaking in mild detergent, rinsing with clean water, and blowing out with compressed air.
N/A Per TTMA Technical Bulletin No. 92 "Inspect pressure relief valves and normal pressure/vacuum valves with sufficient frequency, but no less than once a month, to insure they are operational. Corroded parts must be replaced. Valves that are filled with residue must be cleaned. If venting devices are not operational, do not operate the cargo tank until the venting devices are repaired or replaced. Failure to follow this procedure can result in liquid or vapor leakage and tank damage."

To inspect vent, remove from tank and check for obstructions in the exit port and pressure inlets. Shake vent to ensure roll-over guide block (#5) slides freely up and down. The vacuum disc (#14) is spring-loaded and should open approximately 1/8" to expose vacuum seat when the hex nut (#16) is gripped with a pair of pliers and pulled directly down.

Dirt and residue can be cleaned from the vent by soaking in mild detergent, rinsing with clean water, and blowing out with compressed air.
N/A
Vent Package N/A N/A N/A N/A Combination Vent Packages, consisting of Tiona's all new single purpose vents, are available for all combination manholes with fill. Each vent provides 0.44 sq. in. of venting area. They are easily cleaned, have high capacity, and are available in a variety of materials. These vents have been flow tested and marked in accordance with Nat. Fire Protection Assn. No. 385 (1964) Par. 2263 and No. 407 (1964) Par. 616.
Note N/A N/A N/A N/A While this vent does provide additional inbreathing capacity, it is recommended that positive vents, which will open with the emergency valve, be provided when discharging product with the manhole closed.
Qty Req'd for Discount N/A 4
% Discount at Checkout N/A 5 %